名称 ID 标签 描述 类型 访问 分类
sp_volume_total_text 40B4 Vol totl text A 1 to 8 character description of a special unit of volume, which is based on the special unit of flow to represent total. 读/写 ASCII 2048
fixfreq 40B5 固定频率 A value (in Hertz) that will be indicated on the frequency output for the purpose of a loop test. 读/写 浮点 4096
totctl 40B6 累加器控制 Allows the user to Reset, Stop, or Start all totalizers. NOTE - Inventory totals are NOT reset. 读/写 枚举 4096
fo_scaling_method 4022 FO Scale Method This parameter allows you to scale the frequency output by using freq=flow, pulses/unit, or units/pulse. This parameter must be sent to the device before you make scaling changes. 读/写 枚举 512
fo_polarity 41FB Polarity This parameter allows you to set the polarity of the frequency output. 读/写 枚举 512
dens_tgco 40B8 DTG This parameter represents the Density Temperature Gradient Coefficient (DTG) that is on the T-series sensor tag. 读/写 浮点 8
dens_fqco1 40B9 DFQ1 This parameter represents the Density Frequency Coefficient #1 (DFQ1) that is on the T-series sensor tag. 读/写 浮点 8
dens_fqco2 40BA DFQ2 This parameter represents the Density Frequency Coefficient #2 (DFQ2) that is on the T-series sensor tag. 读/写 浮点 8
flow_tgco 40BB FTG This parameter represents the Flow Temperature Gradient Coefficient (FTG) that is on the T-series sensor tag. 读/写 浮点 8
flow_fqco 40BC FFQ This parameter represents the Flow Frequency Coefficient (FFQ) that is on the T-series sensor tag. 读/写 浮点 8
名称 ID 标签 描述 类型 访问 分类