Name ID Label Description Type Access Class
vol_flow_u_p 4075 Units/Pulse This parameter allows you to scale the frequency output in terms of the number of units of flow required to generate one pulse. R/W Float 512
vtot_digital_units 4078 Vol flo totl unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. R Enum 32
vtot_digital_value 4079 Vol totl R Float 10
vinv_digital_value 407B Vol inventory R Float 10
pres_digital_units 407D Pressure unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 32
pres_digital_value 407E Pressure R Float 10
pres_analog_value 407F AO R/W Float 66
pres_analog_upper_limit 4080 Limite sup. anal. Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions R Float 64
pres_analog_lower_limit 4081 Limite inf. anal. Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions R Float 64
pres_percent_range 4082 % rnge Percentuale di campo - Variabile che traccia la rappresentazione del valore digitale rispetto al campo definito dal valore di campo inferiore e dal valore di campo superiore, per le modalità operative normali. Le unità di questa variabile sono sempre in percentuale. R Float 34