名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
dens_factor | 40FB | Dens factor | A value, between 0.8 and 1.2, that will act as a multiplier for the density. | 读/写 | 浮点 | 8 |
tube_freq | 40FC | Tube | The tube frequency of the sensor measured in Hertz. | 读 | 浮点 | 2 |
tube_amplitude_L | 40FD | LPO | The pickoff voltage of the sensor measured in Voltage. | 读 | 浮点 | 2 |
tube_amplitude_R | 40FE | RPO | The pickoff voltage of the sensor measured in Voltage. | 读 | 浮点 | 2 |
drive_gain | 40FF | Drive | The drive gain of the transmitter. | 读 | 浮点 | 2 |
live_zero | 4100 | Live zero flow | This flow value is not effected by the flow cutoff and is damped at 8 seconds. It is to be used for diagnostic purposes only and is not used in ANY flow calculations or totalization. | 读 | 浮点 | 2 |
board_temp_700 | 4101 | Board Temperature | The board temperature of the core processor. | 读 | 浮点 | 2 |
case_temp | 4102 | Meter Temp: T-Series | The meter temperature of the T-Series sensor. | 读 | 浮点 | 2 |
FD | 4103 | FD | A calibration constant generated during a flowing density calibration. | 读/写 | 浮点 | 8 |
tot_reset | 4104 | Disp. Total Reset | When this parameter is enabled, you can use the display to reset the totalizer. | 读/写 | 枚举 | 256 |