Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
rt_zero | 40C0 | Zero | A value, in microseconds, representing the phase shift between velocity signals from the sensor when measuring zero flow. | R/W | Float | 2 |
zero_offset_units | 40C1 | Zero units | Units for zero offset - always microseconds. | R/W | Unsigned | 32 |
rt_sigma | 40C2 | Std dev | A unitless value which characterizes the amount of deviation between readings during an Auto Zero operation. | R | Float | 2 |
fault_index | 40C3 | Output Type | R/W | Index | 4096 | |
LMV_fault_timeout | 40C5 | Fault Timeout | This parameter defines the number of seconds for which all outputs will hold their last measured value prior to going to the configured fault state. The default is zero seconds. | R/W | Unsigned | 4 |
ao_1_fault_code | 40CA | AO1 Fault indicator | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 4 |
ao_2_fault_code | 40CE | AO2 Fault indicator | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 4 |
fo_fault_code | 40D0 | FO Fault indicator | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 4 |
dig_comm_fault_code | 40D2 | Comm Fault ind. | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) | R/W | Enum | 4 |
ao_1_fault_level | 40CC | mA1 Fault Value | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. The range is 1.0 to 3.6 mA for downscale or 21.0 to 24.0 for upscale. | R/W | Float | 64 |
Name | ID | Label | Description | Type | Access | Class |