Name ID Label Description Type Access Class
dens_upper_range_value 4052 Dens URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
dens_lower_range_value 4053 Dens LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
dens_analog_value_1 4054 Dens anlog valu R/W Float 66
dens_additional_analog_damping_1 4055 Added damp Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. R/W Float 32
dens_percent_range_1 4056 Dens % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
dens_upper_range_value_1 4057 Dens URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
dens_lower_range_value_1 4058 Dens LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
dens_upper_sensor_limit 404C Dens URL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
dens_digital_damping 4059 Dens damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 32
dens_lower_sensor_limit 405A Dens LRL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
Name ID Label Description Type Access Class