Loading…
Name ID Label Description Type Access Class
xmtr_tag_1 411F Ext Dev Tag 1 This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). R/W PackedAscii 128
xmtr_tag_2 4120 Ext Dev Tag 2 This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). R/W PackedAscii 128
poll_var_1 4121 Polled Var 1 This represents the variable code which will be read via HART for the compensation. R/W Enum 128
poll_var_2 4122 Polled Var 2 This represents the variable code which will be read via HART for the compensation. R/W Enum 128
poll_type_code 411D Polling Type This parameter identifies which compensation algorithms will be enabled within the device based on the polling being done. R/W Enum 128
update_rate 4123 Update Rate This parameter is the update rate for process variables through the system. Set the update rate to NORMAL for most applications. Set the update rate to SPECIAL if you are using the device in proving applications or extremely short batch applications. Refer to the user's manual for more information before you change this parameter. R/W Enum 2048
update_rate_var 4124 Update rate var This parameter identifies the transmitter variable that will be updated at 100 Hz. All others will be updated, but at a slower rate. R/W Enum 2048
flow_pres_factor 4125 Flow factr Pressure compensation factor applied to flow rate (% change per PSI). R/W Float 8
dens_pres_factor 4126 Dens factr Pressure compensation factor applied to density (g/Cucm change per PSI). R/W Float 8
zero_pres_factor 4127 Flowcal pressure Pressure at which flow calibration was performed. R/W Float 8
Name ID Label Description Type Access Class