Name ID Label Description Type Access Class
unknown_float 4044 R/W Float 4096
unknown_units 40F8 単位 R/W Enum 4096
mass_rate_factor 40F9 Mass factor A value, between 0.8 and 1.2, that will act as a multiplier for the mass flow rate. R/W Float 8
vol_rate_factor 40FA Vol factor A value, between 0.8 and 1.2, that will act as a multiplier for the volume flow rate. R/W Float 8
dens_factor 40FB Dens factor A value, between 0.8 and 1.2, that will act as a multiplier for the density. R/W Float 8
tube_freq 40FC Tube The tube frequency of the sensor measured in Hertz. R Float 2
tube_amplitude_L 40FD LPO The pickoff voltage of the sensor measured in Voltage. R Float 2
tube_amplitude_R 40FE RPO The pickoff voltage of the sensor measured in Voltage. R Float 2
drive_gain 40FF Drive The drive gain of the transmitter. R Float 2
live_zero 4100 Live zero flow This flow value is not effected by the flow cutoff and is damped at 8 seconds. It is to be used for diagnostic purposes only and is not used in ANY flow calculations or totalization. R Float 2