Name ID Label Description Type Access Class
massflowStatus 4E0E Mass Flow Family Status Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
massflowUpdatePeriod 4E0F Mass Flow Update Period R Time 0
temp_digital_units 4027 Temperature Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. R/W Enum 32
temp_digital_value 4028 Temperature R Float 10
temp_upper_sensor_limit 4030 Temperature Upper Sensor Limit R Float 8
temp_digital_damping 4031 Temperature Damping Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 32
temp_lower_sensor_limit 4032 Temperature Lower Sensor Limit Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
temp_minimum_span 4033 Temperature Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
temperatureClassificationCode 4E10 Temperature Classification Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
temperatureFamily 4E11 Temperature Family Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 2048
Name ID Label Description Type Access Class