Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
do_index | 41B3 | DO index | R/W | Index | 4096 | |
flow_switch_hysteresis | 4563 | Hysteresis (0.1-10.0) | If the hysteresis is set to 5%, no change of the Discrete Output state occurs when the flow rate is within +-5% of the setpoint. If the setpoint is 100 lb/min and the first reading is below 95 lb/min, the flow switch turns On and will stay On until the flow rate rises above 105 lb/min. At this point it turns Off, and will stay off until the flow rate drops below 95 lb/min. | R/W | Float | 8 |
chan_a | 418D | Назначение | This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2, Channel B is terminals 3 and 4, and Channel C is terminals 5 and 6. | R | Enum | 64 |
chan_b | 418E | Назначение | This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2, Channel B is terminals 3 and 4, and Channel C is terminals 5 and 6. | R/W | Enum | 64 |
chan_c | 418F | Назначение | This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2, Channel B is terminals 3 and 4, and Channel C is terminals 5 and 6. | R | Enum | 64 |
current_ed_curve | 4202 | Активная матрица | The Enhanced Density Curve that is currently selected. | R/W | Enum | 2048 |
ed_std_vol_flow_digital_value | 4203 | Temperature-Corrected Volume Flow Rate (Concentration) | R | Float | 10 | |
ed_std_vol_flow_analog_value | 4204 | Temperature-Corrected Volume Flow Rate (Concentration) | R/W | Float | 66 | |
ed_std_vol_flow_analog_value_1 | 4205 | Temperature-Corrected Volume Flow Rate (Concentration) | R/W | Float | 66 | |
ed_std_vtot_digital_value | 4206 | Temperature-Corrected Volume Total (Concentration) | R | Float | 10 | |
Name | ID | Label | Description | Type | Access | Class |