Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
fo_polarity | 41D1 | Polarity | This parameter allows you to set the polarity of the frequency output. | R/W | Enum | 512 |
api_ctl_table_type | 41DE | API 2540 CTL Table Type | This parameter allows you to select the 2540 CTL Table Type for API. | R/W | Enum | 2048 |
api_thermal_exp_coeff | 41DF | API Thermal Expansion Coefficient | This parameter allows you to select the Thermal Expansion Coefficient API. The units are the inverse of the temperature user units. | R/W | Float | 8 |
api_ref_temp | 41E0 | API Reference Temperature | This parameter allows you to select the Reference Termperature for API. The units must be the same as the temperature user units. | R/W | Float | 8 |
api_ctl | 41DA | CTL | This parameter displays the Correction of Temperature on a Liquid. | R | Float | 2 |
enable_api | 41E1 | Enable API | This parameter allows you to enable/disable the api feature | R/W | Enum | 8 |
enable_pres_comp | 41D2 | Enable Pressure Comp | This parameter allows you to enable/disable the pressure correction feature | R/W | Enum | 8 |
static_pressure | 41D3 | Static Pressure | This parameter allows you to enter a static pressure when using the pressure correction feature | R/W | Float | 8 |
enable_extern_temp | 41E4 | Enable Ext Temp | This parameter allows you to enable/disable the external temperature feature | R/W | Enum | 8 |
static_temperature | 41E5 | Static Temperature | This parameter allows you to enter a static temperature when using the external temperature feature | R/W | Float | 8 |