Loading…
Name ID Label Description Type Access Class
drive_lower_range_value 4191 LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
drive_upper_sensor_limit 41B0 USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
drive_lower_sensor_limit 41B1 LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
drive_minimum_span 41B2 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
poll_ctrl_1 4193 Poll Control 1 A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. R/W Enum 128
poll_ctrl_2 4194 Poll Control 2 A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. R/W Enum 128
xmtr_tag_1 419D Ext Dev Tag 1 This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). R/W PackedAscii 128
xmtr_tag_2 419F Ext Dev Tag 2 This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). R/W PackedAscii 128
poll_var_1 419C Polled Var 1 This represents the variable code which will be read via HART for the compensation. R/W Enum 128
poll_var_2 419E Polled Var 2 This represents the variable code which will be read via HART for the compensation. R/W Enum 128
Name ID Label Description Type Access Class