名称 ID 标签 描述 类型 访问 分类
drive_lower_sensor_limit 41B1 LSL 传感器下限值——定义上限值的最小可用数值。 浮点 8
drive_minimum_span 41B2 最小范围 最小范围值——定义上限值和下限值之间允许的最小差。 浮点 8
poll_ctrl_1 4193 Poll Control 1 A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. 读/写 枚举 128
poll_ctrl_2 4194 Poll Control 2 A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. 读/写 枚举 128
xmtr_tag_1 419D Ext Dev Tag 1 This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). 读/写 压缩文本 128
xmtr_tag_2 419F Ext Dev Tag 2 This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). 读/写 压缩文本 128
poll_var_1 419C Polled Var 1 This represents the variable code which will be read via HART for the compensation. 读/写 枚举 128
poll_var_2 419E Polled Var 2 This represents the variable code which will be read via HART for the compensation. 读/写 枚举 128
poll_type_code 4192 Polling Type This parameter identifies which compensation algorithms will be enabled within the device based on the polling being done. 读/写 枚举 128
update_rate 4186 Update Rate This parameter is the update rate for process variables through the system. Set the update rate to NORMAL for most applications. Set the update rate to SPECIAL if you are using the device in proving applications or extremely short batch applications. Refer to the user's manual for more information before you change this parameter. 读/写 枚举 2048
名称 ID 标签 描述 类型 访问 分类