名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
alarm2_type | 40AD | Event2 type | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. | 读/写 | 枚举 | 1024 |
alarm1_setpoint | 40A4 | Event1 setpoint | A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. | 读/写 | 浮点 | 16 |
alarm2_setpoint | 40AB | Event2 setpoint | A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. | 读/写 | 浮点 | 16 |
alarm1_varcode | 40A6 | Event1 var | Assigns a process variable to event 1 or event 2. | 读/写 | 索引 | 16 |
alarm2_varcode | 40AC | Event2 var | Assigns a process variable to event 1 or event 2. | 读/写 | 索引 | 16 |
rt_freq | 40B5 | Pres freq | The frequency, in Hertz, presently being indicated on the frequency output. | 读 | 浮点 | 514 |
unknown_serial_number | 4039 | 传感器序列号 | 读/写 | 无符号 | 4096 | |
unknown_float | 4035 | 读/写 | 浮点 | 4096 | ||
unknown_units | 40B6 | 单位 | 读/写 | 枚举 | 4096 | |
mass_rate_factor | 40B7 | Mass factor | A value, between 0.8 and 1.2, that will act as a multiplier for the mass flow rate. | 读/写 | 浮点 | 8 |