Name ID Label Description Type Access Class
minv_digital_value 4048 Mass inventory R Float 2
vol_flow_digital_units 404A Vol flo unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. R/W Enum 32
vol_flow_digital_value 404B Vol flo R Float 2
vol_flow_digital_cutoff 404D Vol flo cutoff The volume flow rate below which the frequency/pulse output indicates zero flow, and below which totalizers stop counting. R/W Float 8
vol_flow_analog_value 404E Vol flo anlog valu R/W Float 66
vol_flow_analog_upper_limit 404F Límite sup. analóg. Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions R Float 64
vol_flow_analog_lower_limit 4050 Límite inf. analóg. Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions R Float 64
vol_flow_additional_analog_damping 4051 Added damp Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. R/W Float 32
vol_flow_percent_range 4052 Vol flo % rnge Porcentaje de rango: Variable que rastrea la representación del valor digital con respecto al rango definido por el valor de rango inferior y el valor de rango superior, para modos de funcionamiento normales. Las unidades de esta variable siempre son en porcentaje. R Float 34
vol_flow_upper_range_value 4053 Vol flo URV Valor de rango superior: Define el punto final de funcionamiento del cual se derivan el valor analógico y el punto 100% del rango de porcentaje. Además, el valor de rango superior define un punto final de funcionamiento del que se derivan las alarmas asociadas con el valor analógico y las alarmas asociadas con la representación del valor digital. R/W Float 32
Name ID Label Description Type Access Class