Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
drive_lower_sensor_limit | 409B | Lower Sensor Limit | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
drive_minimum_span | 409C | Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
ext_temp_digital_value | 409F | External Temperature | R | Float | 10 | |
mmi_flange_type | 40BC | Sensor Flange | Configuration information identifying the flange material used with the sensor. Informational purposes only - does not affect flowmeter operation. | R/W | Enum | 2048 |
liner_matl | 40BD | Tube Lining | Configuration information identifying any liner material used with the sensor. Informational purposes only - does not affect flowmeter operation. | R/W | Enum | 2048 |
sensor_model | 40BE | Sensor Model | Configuration information identifying the sensor model installed. Informational purposes only - does not affect flowmeter operation. | R/W | PackedAscii | 2048 |
sensor_matl | 40BF | Tube Wetted Material | Configuration information identifying the material of which the sensor is constructed. Informational purposes only - does not affect flowmeter operation. | R/W | Enum | 2048 |
sp_mass | 40C6 | Base Unit | A standard engineering unit that serves as the mass component in a special unit. | R/W | Enum | 32 |
sp_mass_time | 40C7 | Base Time | A standard unit of time (seconds, minutes, hours, or days) that serves as the time component in a special unit. | R/W | Enum | 32 |
sp_mass_fact | 40C8 | Conversion Factor | A programmable divider for the base mass unit in a special unit. | R/W | Float | 32 |