Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
dens_digital_damping | 4042 | Dens damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 32 |
dens_lower_sensor_limit | 4043 | Dens LRL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
dens_minimum_span | 4044 | Dens min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
minv_digital_value | 4046 | Mass inventory | R | Float | 10 | |
vol_flow_digital_units | 4048 | Vol flo unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | R/W | Enum | 32 |
vol_flow_digital_value | 4049 | Vol flo | R | Float | 10 | |
vol_flow_digital_cutoff | 404B | Vol flo cutoff | The volume flow rate below which the frequency/pulse output indicates zero flow, and below which totalizers stop counting. Cutoffs can also be configured for the mA output(s) (the AO cutoffs). An AO cutoff is active only if the process variable assigned to the output is mass flow or volume flow. | R/W | Float | 8 |
vol_flow_analog_value | 404C | Vol flo anlog valu | R/W | Float | 66 | |
vol_flow_analog_upper_limit | 404D | Anlog upr limit | Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions | R | Float | 64 |
vol_flow_analog_lower_limit | 404E | Anlog lor limit | Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions | R | Float | 64 |
Name | ID | Label | Description | Type | Access | Class |