Name ID Label Description Type Access Class
enable_pres_comp 41BC Enable Pressure Comp This parameter allows you to enable/disable the pressure correction feature R/W Enum 8
static_pressure 41BD Static Pressure This parameter allows you to enter a static pressure when using the pressure correction feature R/W Float 8
enable_extern_temp 41CE Enable Ext Temp This parameter allows you to enable/disable the external temperature feature R/W Enum 8
static_temperature 41CF Static Temperature This parameter allows you to enter a static temperature when using the external temperature feature R/W Float 8
flow_switch_setpoint 4100 Flow Switch Setpoint This parameter can be used to trigger a discrete output when the mass flow rate exceeds the configured setpoint. There is a fixed hysteresis of 5% for this setpoint. R/W Float 16
do1_assignment 41D0 DO is This parameter identifies which condition the discrete output will act upon. R/W Enum 1024
do1_state 41D1 DO is This parameter identifies the state of the discrete output. R/W Enum 1024
do_index 41D2 DO index R/W Index 4096
board_temp_units 41E4 Temp unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. R Enum 32
Process_Variable_Code_0 41ED Var Code 0 The process variable of which display precision can be set R Enum 2048
Name ID Label Description Type Access Class