Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
pv_disp15 | 40EE | Disp. Var #15 is | This parameter allows you to select the process variables that will appear on the display. Up to 15 process variables can be configured to appear on the display. They can be accessed by using the scroll button. | R/W | Enum | 256 |
rs485_protocol | 40EF | RS485 Protocol | This parameter defines the protocol that will be used on the RS485 physical layer. | R/W | Enum | 2048 |
rs485_baudrate | 40F0 | RS485 Baudrate | This parameter defines the baud rate for the protocol that will be used on the RS485 physical layer. | R/W | Enum | 2048 |
rs485_parity | 40F1 | RS485 Parity | This parameter defines the parity for the protocol that will be used on the RS485 physical layer. | R/W | Enum | 2048 |
rs485_stop | 40F2 | RS485 Stop Bits | This parameter defines the number of stop bits for the protocol that will be used on the RS485 physical layer. | R/W | Unsigned | 2048 |
modbus_address | 41E3 | Modbus Address | This parameter defines the Modbus slave address. Addresses 1-15,32-47,64-79, or 96-110 are allowed | R/W | Unsigned | 2048 |
sens_type_code | 4086 | Sensor Type | This parameter indicates which type of sensor is being used for process measurement. | R/W | Enum | 8 |
output_opt_brd | 40F3 | Output Opt. Brd. | This parameter represents the various types of output option boards that are available. | R | Enum | 2048 |
poll_ctrl_1 | 40F4 | Poll Control 1 | A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. | R/W | Enum | 128 |
poll_ctrl_2 | 40F6 | Poll Control 2 | A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. | R/W | Enum | 128 |
Name | ID | Label | Description | Type | Access | Class |