drive_percent_range 406F % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
drive_upper_range_value 4070 URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
drive_lower_range_value 4071 LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
drive_upper_sensor_limit 4072 USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
drive_lower_sensor_limit 4073 LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
drive_minimum_span 4074 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
mmi_flange_type 4078 Flange Configuration information identifying the flange material used with the sensor. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048
liner_matl 4079 Liner matl Configuration information identifying any liner material used with the sensor. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048
sensor_model 407A Snsr model Configuration information identifying the sensor model installed. Informational purposes only - does not affect flowmeter operation. R/W PackedAscii 2048
sensor_matl 407B Snsr matl Configuration information identifying the material of which the sensor is constructed. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048