Loading…
Name ID Label Description Type Access Class
analog_output_fixed1 0FCB AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 67
analog_output_fixed2 0FCC AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 67
analog_output_fixed3 0FCD AO fixed Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. R BitEnum 67
primary_variable_code 0FD0 PV is Primary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Primary Variable dynamic variable R/W Index 128
secondary_variable_code 0FD1 SV is Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable R/W Index 128
tertiary_variable_code 0FD2 TV is Tertiary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Tertiary Variable dynamic variable R/W Index 128
fourth_variable_code 0FD3 QV is Fourth Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Fourth Variable dynamic variable R/W Index 128
transmitter_variable_code 0FD6 Index into Dynamic Variables Array- An index that identifies a Field Device Variable that is dynamic with respect to time, with no user input R/W Index 4096
response_preambles 0FE2 Num Preambles Number of Response Preambles- Number of Preambles to be sent in the response message from the Field Device to the Host R/W Unsigned 128
analog_output_code 0FE4 Analog Output Number- Index into an array of Analog Outputs R/W Index 4096
Name ID Label Description Type Access Class