Name ID Label Description Type Access Class
flow_switch_setpoint 4100 Flow Switch Setpoint This parameter can be used to trigger a discrete output when the mass flow rate exceeds the configured setpoint. There is a fixed hysteresis of 5% for this setpoint. R/W Float 16
do1_assignment 41D0 DO is This parameter identifies which condition the discrete output will act upon. R/W Enum 1024
do1_state 41D1 DO is This parameter identifies the state of the discrete output. R/W Enum 1024
do_index 41D2 DO index R/W Index 4096
board_temp_units 41E4 Temp unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. R Enum 32
unique_device_type_code 07ED R/W Enum 4096
rosemount_model_code 07F5 R/W Enum 4096
rosemount_analytical_model_code 07F6 R/W Enum 4096
kayray_model_code 07F7 R/W Enum 4096
micro_motion_model_code 07F8 R/W Enum 4096