Name ID Label Description Type Access Class
dens_fqco1 4091 DFQ1 This parameter represents the Density Frequency Coefficient #1 (DFQ1) that is on the T-series sensor tag. R/W Float 8
dens_fqco2 4092 DFQ2 This parameter represents the Density Frequency Coefficient #2 (DFQ2) that is on the T-series sensor tag. R/W Float 8
flow_tgco 4093 FTG This parameter represents the Flow Temperature Gradient Coefficient (FTG) that is on the T-series sensor tag. R/W Float 8
flow_fqco 4094 FFQ This parameter represents the Flow Frequency Coefficient (FFQ) that is on the T-series sensor tag. R/W Float 8
max_zero 4095 Zero time The number of readings collected from the sensor during an Auto Zero operation. R/W Unsigned 12
pulse_width 4096 Max pulse width A programmable time period, in seconds, that defines the crossover frequency for the frequency output, where Crossover freq. = 1 / (2 x Pulse width). Below the crossover, the output has a constant ON state, and an OFF state that varies with frequency. R/W Float 512
tempcal 4097 Temp cal factr A 14-character factor that describes the slope and offset of the linear output representing flow tube temperature. R/W ASCII 32
rt_zero 4098 Zero A value, in microseconds, representing the phase shift between velocity signals from the sensor when measuring zero flow. R/W Float 10
zero_offset_units 4099 Zero units Units for zero offset - always microseconds. R/W Unsigned 32
rt_sigma 409A Std dev A unitless value which characterizes the amount of deviation between readings during an Auto Zero operation. R Float 10