Loading…
Name ID Label Description Type Access Class
output_opt_brd 40F3 Output Opt. Brd. This parameter represents the various types of output option boards that are available. R Enum 2048
poll_ctrl_1 40F4 Poll Control 1 A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. R/W Enum 128
poll_ctrl_2 40F6 Poll Control 2 A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. R/W Enum 128
xmtr_tag_1 40F7 Ext Dev Tag 1 This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). R/W PackedAscii 128
xmtr_tag_2 40F8 Ext Dev Tag 2 This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). R/W PackedAscii 128
poll_var_1 40F9 Polled Var 1 This represents the variable code which will be read via HART for the compensation. R/W Enum 128
poll_var_2 40FA Polled Var 2 This represents the variable code which will be read via HART for the compensation. R/W Enum 128
poll_type_code 40F5 Polling Type This parameter identifies which compensation algorithms will be enabled within the device based on the polling being done. R/W Enum 128
update_rate 40FB Update Rate This parameter is the update rate for process variables through the system. Set the update rate to NORMAL for most applications. Set the update rate to SPECIAL if you are using the device in proving applications or extremely short batch applications. Refer to the user's manual for more information before you change this parameter. R/W Enum 2048
update_rate_var 40FC Update rate var This parameter identifies the transmitter variable that will be updated at 100 Hz. All others will be updated, but at a slower rate. R/W Enum 2048
Name ID Label Description Type Access Class