Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
fault_index | 4060 | Output Type | R/W | Index | 4096 | |
ao_1_fault_code | 46E3 | 故障アクション | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 12 |
ao_2_fault_code | 46E9 | 故障アクション | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 12 |
dig_comm_fault_code | 46FB | 故障アクション | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) | R/W | Enum | 12 |
discrete_output_fault_code | 46FC | Fault Action | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) | R/W | Enum | 12 |
ao_1_fault_level | 46E4 | 故障レベル | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. The range is 3.2 to 3.6 mA for downscale or 21.0 to 21.5 for upscale. | R/W | Float | 64 |
ao_2_fault_level | 46EA | 故障レベル | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. The range is 3.2 to 3.6 mA for downscale or 21.0 to 21.5 for upscale. | R/W | Float | 64 |
LMV_fault_timeout | 4064 | Fault Timeout | This parameter defines the number of seconds for which all outputs will hold their last measured value prior to going to the configured fault state. The default is zero seconds. | R/W | Unsigned | 12 |
history_0 | 4A3B | Alarm Event Log Index | R | Unsigned | 2048 | |
history_1 | 4A3C | Alarm Event Log Index | R | Unsigned | 2048 | |
Name | ID | Label | Description | Type | Access | Class |