Name ID Label Description Type Access Class
mass_flow_digital_damping 48B0 Flow Damping Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 32
mass_flow_upper_sensor_limit 42CD Mass Flow Upper Sensor Limit Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
mass_flow_lower_sensor_limit 42CF Mass Flow Lower Sensor Limit Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
mass_flow_minimum_span 485D Mass Flow Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
ednetmassflowClassificationCode 48B2 ED Net Mass Flow Classification Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
ednetmassflowFamily 48B3 ED Net Mass Flow Family Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 2048
ednetmassflowPDQ 4236 ED Net Mass Flow PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 10
ednetmassflowLS 48B4 ED Net Mass Flow LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
ednetmassflowStatus 48B5 ED Net Mass Flow Family Status Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
ednetmassflowUpdatePeriod 48B6 ED Net Mass Flow Update Period R Time 0
Name ID Label Description Type Access Class