Name ID Label Description Type Access Class
time_period_collectionLS 49B7 Sensor Time Period LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
time_period_collectionStatus 49B8 Sensor Time Period Family Status Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 10
time_period_collectionUpdatePeriod 49B9 Sensor Time Period Update Period R Time 0
percentRange_1 49C1 Secondary Variable Percent Range Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
transfer_function_1 49C2 Xfer fnctn Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. R Enum 32
upperRange_value_1 484C Secondary Variable Upper Range Value Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
lowerRange_value_1 484D Secondary Variable Lower Range Value Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
loopCurrent_1 49C3 MAO2 Loop Current- Loop current value as perceived by the device. R/W Float 66
loop_alarm_code_1 49C4 AO Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
loop_flags_1 49C5 Channel flags Analog Channel Flags- Defines the characteristics of the Analog Channel R BitEnum 64
Name ID Label Description Type Access Class