Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
Last_Cleared | 406C | Last Cleared | R | Unsigned | 4096 | |
rt_zero | 405B | Текущ. нулевое знач. | A value, in microseconds, representing the phase shift between velocity signals from the sensor when measuring zero flow. | R/W | Float | 10 |
rt_sigma | 405D | Standard Deviation | A unitless value which characterizes the amount of deviation between readings during an Auto Zero operation. | R | Float | 10 |
factory_zero_offset | 405E | Factory zero offset | Factory zero offset value - always microseconds. | R/W | Float | 10 |
fault_index | 4060 | Output Type | R/W | Index | 4096 | |
ao_1_fault_code | 46E3 | Действие при сбое | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 12 |
ao_2_fault_code | 46E9 | Действие при сбое | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 12 |
dig_comm_fault_code | 46FB | Действие при сбое | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) | R/W | Enum | 12 |
discrete_output_fault_code | 46FC | Fault Action | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) | R/W | Enum | 12 |
ao_1_fault_level | 46E4 | Уровень ошибки | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. The range is 3.2 to 3.6 mA for downscale or 21.0 to 21.5 for upscale. | R/W | Float | 64 |
Name | ID | Label | Description | Type | Access | Class |