Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
temp_additional_analog_damping | 4028 | Added Damping | Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. | R/W | Float | 32 |
temp_percent_range | 4029 | Temperature Percent Range | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
temp_upper_range_value | 402A | Temperature Upper Range Value | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
temp_lower_range_value | 402B | Temperature Lower Range Value | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
temp_analog_value_1 | 419C | Temperature mA Value | R/W | Float | 66 | |
temp_additional_analog_damping_1 | 419D | Added Damping | Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. | R/W | Float | 32 |
temp_percent_range_1 | 419E | Temperature Percent Range | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
temp_upper_range_value_1 | 419F | Temperature Upper Range Value | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
temp_lower_range_value_1 | 41A0 | Temperature Lower Range Value | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
temp_upper_sensor_limit | 402C | Temperature Upper Sensor Limit | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |