名称 ID 标签 描述 类型 访问 分类
alarm2_type 40CB Event Type Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. 读/写 枚举 1024
alarm1_setpoint 40C2 Setpoint A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. 读/写 浮点 16
alarm2_setpoint 40C9 Setpoint A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. 读/写 浮点 16
alarm1_varcode 40C4 Variable Assigns a process variable to event 1 or event 2. 读/写 索引 16
alarm2_varcode 40CA Variable Assigns a process variable to event 1 or event 2. 读/写 索引 16
rt_freq 40D3 Present Frequency Output The frequency, in Hertz, presently being indicated on the frequency output. 浮点 514
unknown_serial_number 4037 Sensor Serial Number 读/写 无符号 4096
unknown_float 4031 读/写 浮点 4096
unknown_units 4083 单位 读/写 枚举 4096
fcf1 40D4 读/写 无符号 32
名称 ID 标签 描述 类型 访问 分类