Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
mass_flow_percent_range_1 | 4198 | Mass Flow Percent Range | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
alarm_select | 4010 | AO Alrm typ | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. | R | Enum | 2 |
mmi_transfer_function | 4011 | Xfer fnctn | R/W | Enum | 32 | |
analog_units | 4012 | Anlog unit | R/W | Enum | 32 | |
mass_flow_upper_range_value | 4013 | Mass Flow Upper Range Value | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
mass_flow_upper_range_value_1 | 4199 | Mass Flow Upper Range Value | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
mass_flow_lower_range_value | 4014 | Mass Flow Lower Range Value | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
mass_flow_lower_range_value_1 | 419A | Mass Flow Lower Range Value | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
mass_flow_digital_damping | 4015 | Flow Damping | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 32 |
serial_number | 4016 | Sensor Serial Number | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |