Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
vol_flow_lower_range_value_1 | 41AC | Vol flo LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
vol_flow_upper_sensor_limit | 404A | Vol flo URL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
vol_flow_lower_sensor_limit | 4053 | Vol flo LRL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
vol_flow_minimum_span | 4054 | Vol flo min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
vol_flow_hzfreq | 4055 | Freq factr | The number of cycles, in Hertz, that equal a proportional flow rate represented by the frequency/pulse output. | R/W | Float | 512 |
vol_flow_hzrate | 4056 | Rate factr | The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. | R/W | Float | 512 |
vtot_digital_units | 4058 | Vol flo totl unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 32 |
vtot_digital_value | 4059 | Vol totl | R | Float | 2 | |
vtot_hzfreq | 405A | Freq factr | The number of cycles, in Hertz, that equal a proportional flow rate represented by the frequency/pulse output. | R/W | Float | 512 |
vtot_hzrate | 405B | Rate factr | The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. | R/W | Float | 512 |
Name | ID | Label | Description | Type | Access | Class |