名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
alarm2_type | 40CB | Event2 type | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. | 读/写 | 枚举 | 1024 |
alarm1_setpoint | 40C2 | Event1 setpoint | For the Model RFT9739, a programmable flow rate, total, density, temperature, differential pressure, or viscosity at which an output set to represent event 1 or event 2 switches states. | 读/写 | 浮点 | 16 |
alarm2_setpoint | 40C9 | Event2 setpoint | For the Model RFT9739, a programmable flow rate, total, density, temperature, differential pressure, or viscosity at which an output set to represent event 1 or event 2 switches states. | 读/写 | 浮点 | 16 |
alarm1_varcode | 40C4 | Event1 var | Assigns flow rate, total, density, temperature, differential pressure, or viscosity to event 1 or event 2. | 读/写 | 索引 | 16 |
alarm2_varcode | 40CA | Event2 var | Assigns flow rate, total, density, temperature, differential pressure, or viscosity to event 1 or event 2. | 读/写 | 索引 | 16 |
rt_freq | 40D3 | Pres freq | The frequency, in Hertz, presently being indicated on the frequency output. | 读 | 浮点 | 514 |
unknown_serial_number | 4037 | 传感器序列号 | 读/写 | 无符号 | 4096 | |
unknown_float | 4031 | 读/写 | 浮点 | 4096 | ||
unknown_units | 4083 | 单位 | 读/写 | 枚举 | 4096 | |
fcf1 | 40D4 | 读/写 | 无符号 | 32 | ||
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |