Loading…
Name ID Label Description Type Access Class
met_direct 409A Flo direction A control that enables the user to determine whether the frequency/pulse output and totalizers will indicate forward, reverse, or bi-directional flow. R/W Enum 32
slughi 409B Slug high limit A programmable high limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. R/W Float 8
sluglo 409C Slug low limit A programmable low limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. R/W Float 8
flocal 409D FlowCal A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. R/W ASCII 32
ma_1_cutoff 401D PV AO cutoff The mass or volume flow rate below which a milliamp output representing flow indicates zero flow. R/W Float 8
ma_2_cutoff 401F SV AO cutoff The mass or volume flow rate below which a milliamp output representing flow indicates zero flow. R/W Float 8
sp_volume 409E Base vol unit A standard engineering unit that serves as the volume component in a special unit. R/W Enum 32
sp_volume_time 409F Base vol time A standard unit of time (seconds, minutes, hours, or days) that serves as the time component in a special unit. R/W Enum 32
sp_volume_fact 40A0 Vol flo conv factr A programmable multiplier for the base volume unit in a special unit. R/W Float 32
sp_volume_rate_text 40A1 Vol flo text A 1 to 4 character description of a special unit of flow. R/W ASCII 2048
Name ID Label Description Type Access Class