Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
sp_rate_text | 4038 | Flo text | A 1 to 4 character description of a special unit of flow. | R/W | ASCII | 2048 |
sp_total_text | 4039 | Totl text | A 1 to 4 character description of a special unit of mass/volume, which is based on the special unit of flow. | R/W | ASCII | 2048 |
met_direct | 403A | Vazão direcionada | A control that enables the user to determine whether the frequency/pulse output and totalizers will indicate forward, reverse, or bi-directional flow. | R/W | Enum | 32 |
hzfreq | 403B | Fator de frequência | The number of cycles, in Hertz, that equal a proportional flow rate represented by the frequency/pulse output. | R/W | Float | 512 |
hzrate | 403C | Fator de taxa | The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. | R/W | Float | 512 |
slughi | 403D | Slug high limit | A programmable high limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. | R/W | Float | 8 |
sluglo | 403E | Slug low limit | A programmable low limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. | R/W | Float | 8 |
flocal | 403F | FlowCal | A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. | R/W | ASCII | 32 |
ma_1_cutoff | 4016 | PV AO cutoff | The mass or volume flow rate below which a milliamp output representing flow indicates zero flow. | R/W | Float | 8 |
fixfreq | 4041 | Frequência fixa | A value (in Hertz) that will be indicated on the frequency output for the purpose of a loop test. | R/W | Float | 4096 |
Name | ID | Label | Description | Type | Access | Class |