Loading…
Name ID Label Description Type Access Class
dens_upper_sensor_limit 4029 Dens URL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
dens_lower_sensor_limit 402E Dens LRL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
dens_minimum_span 402F Dens min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
mmi_flange_type 4031 Flange Configuration information identifying the flange material used with the sensor. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048
liner_matl 4032 Liner matl Configuration information identifying any liner material used with the sensor. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048
sensor_model 4033 Snsr model Configuration information identifying the sensor model installed. Informational purposes only - does not affect flowmeter operation. R/W PackedAscii 2048
sensor_matl 4034 Snsr matl Configuration information identifying the material of which the sensor is constructed. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048
sp_flow 4035 Base flow unit A standard engineering unit that serves as the mass or volume component in a special unit. R/W Enum 32
sp_time 4036 Base time unit A standard unit of time (seconds, minutes, hours, or days) that serves as the time component in a special unit. R/W Enum 32
sp_fact 4037 Flo conv factr A programmable multiplier for the base unit in a special unit. R/W Float 32
Name ID Label Description Type Access Class