Loading…
Name ID Label Description Type Access Class
flow_digital_units 4006 Flo unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 32
flow_digital_value 4007 Flo R Float 2
flow_digital_cutoff 4009 Flo cutoff The flow rate below which the frequency/pulse output indicates zero flow. R/W Float 8
mmi_flow_analog_value 400A Flo anlog valu R/W Float 66
mmi_flow_percent_range 400B Flo % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
alarm_select 400C Alarm select Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. R Enum 2
mmi_flow_upper_range_value 400D Flo URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
mmi_flow_lower_range_value 400E Flo LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
flow_digital_damping 400F Flo damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 32
serial_number 4010 Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R/W Unsigned 2048
Name ID Label Description Type Access Class