Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
enable_pres_comp | 4138 | Pressure Compensation | This parameter allows you to enable/disable the pressure correction feature | R/W | Enum | 8 |
static_pressure | 4139 | Compensation Pressure | This parameter allows you to enter a static pressure when using the pressure correction feature | R/W | Float | 8 |
enable_extern_temp | 413A | External Temperature | This parameter allows you to enable/disable the external temperature feature. | R/W | Enum | 8 |
static_temperature | 413B | Correction Temperature | This parameter allows you to enter a static temperature when using the external temperature feature. | R/W | Float | 8 |
flow_switch_setpoint | 413C | Setpoint | This parameter can be used to trigger a discrete output when the mass flow rate exceeds the configured setpoint. There is a fixed hysteresis of 5% for this setpoint. | R/W | Float | 16 |
flow_switch_variable_assignment | 413D | Source | The variable that is monitored to determine if a flow switch has occurred. | R/W | Enum | 8 |
do1_assignment | 413E | Assignment | This parameter identifies which condition the discrete output will act upon. | R/W | Enum | 1024 |
do1_state | 413F | Discrete Output State | This parameter identifies the state of the discrete output. | R/W | Enum | 2 |
do1_polarity | 4140 | Polarity | This parameter allows you to set the polarity of the discrete output. | R/W | Enum | 1024 |
do1_FaultIndication | 4141 | Fault Action | The state to which the discrete output will be set if the transmitter detects a fault with 'Alert Severity' = 'Fault'. If 'None' is selected, the behavior of the discrete output will be controlled by 'Discrete Output Source'. | R/W | Enum | 1024 |
Name | ID | Label | Description | Type | Access | Class |