Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
fcf_abort_code_2 | 4942 | Abort Code | Abort Code | R | Enum | 2 |
fcf_time_2 | 4956 | Transmitter Running Hours at Test | The transmitter's power on time at the time of the test. | R | Unsigned | 2 |
fcf_lpo_norm_2 | 4905 | Left Pickoff Stiffness | The left pickoff stiffness normalized to the baseline. | R | Float | 2 |
fcf_rpo_norm_2 | 4919 | Right Pickoff Stiffness | The right pickoff stiffness normalized to the baseline. | R | Float | 2 |
fcf_run_number_3 | 48F2 | Meter Verification Run Counter | The run counter for this Meter Verification run. | R | Unsigned | 2 |
fcf_test_result_3 | 492F | Test Result | Test Result | R | Enum | 2 |
fcf_abort_code_3 | 4943 | Abort Code | Abort Code | R | Enum | 2 |
fcf_time_3 | 4957 | Transmitter Running Hours at Test | The transmitter's power on time at the time of the test. | R | Unsigned | 2 |
fcf_lpo_norm_3 | 4906 | Left Pickoff Stiffness | The left pickoff stiffness normalized to the baseline. | R | Float | 2 |
fcf_rpo_norm_3 | 491A | Right Pickoff Stiffness | The right pickoff stiffness normalized to the baseline. | R | Float | 2 |
Name | ID | Label | Description | Type | Access | Class |