Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
xmtr_tag_2 | 4131 | External Device Tag 2 | This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). | R/W | PackedAscii | 128 |
poll_var_1 | 4132 | Polled Variable #1 | This represents the variable code which will be read via HART for the compensation. | R/W | Enum | 128 |
poll_var_2 | 4133 | Polled Variable #2 | This represents the variable code which will be read via HART for the compensation. | R/W | Enum | 128 |
poll_type_code | 4134 | Polling Type | This parameter identifies which compensation algorithms will be enabled within the device based on the polling being done. | R/W | Enum | 128 |
flow_pres_factor | 4135 | Flow Pressure Factor | Pressure compensation factor applied to flow rate (% change per PSI). | R/W | Float | 8 |
dens_pres_factor | 4136 | Density Pressure Factor | Pressure compensation factor applied to density (g/Cucm change per PSI). | R/W | Float | 8 |
zero_pres_factor | 4137 | Flow Calibration Pressure | Pressure at which flow calibration was performed. | R/W | Float | 8 |
enable_pres_comp | 4138 | Enable Pressure Compensation | This parameter allows you to enable/disable the pressure correction feature | R/W | Enum | 8 |
static_pressure | 4139 | Static Pressure | This parameter allows you to enter a static pressure when using the pressure correction feature | R/W | Float | 8 |
enable_extern_temp | 413A | Enable External Temperature | This parameter allows you to enable/disable the external temperature feature | R/W | Enum | 8 |
Name | ID | Label | Description | Type | Access | Class |