Name ID Label Description Type Access Class
static_pressure 4139 Static Pressure This parameter allows you to enter a static pressure when using the pressure correction feature R/W Float 8
enable_extern_temp 413A Enable Ext Temp This parameter allows you to enable/disable the external temperature feature R/W Enum 8
static_temperature 413B Static Temperature This parameter allows you to enter a static temperature when using the external temperature feature R/W Float 8
flow_switch_setpoint 413C Flow Switch Setpoint This parameter can be used to trigger a discrete output when the mass flow rate exceeds the configured setpoint. There is a fixed hysteresis of 5% for this setpoint. R/W Float 16
flow_switch_variable_assignment 413D Flow Switch Variable Assignment R/W Enum 8
do1_assignment 413E DO 1 is This parameter identifies which condition the discrete output will act upon. R/W Enum 1024
do1_state 413F DO is This parameter identifies the state of the discrete output. R/W Enum 1024
do1_polarity 4140 DO 1 Polarity This parameter allows you to set the polarity of the discrete output. R/W Enum 1024
do1_FaultIndication 4141 DO Fault Indication R/W Enum 1024
do_index 4142 DO index R/W Index 4096