Name ID Label Description Type Access Class
dummy_menu_entry 1B6D Non applicabile R Enum 0
special_application 402E Special Application Oxygen modification means that working cavities of transmitters and parts of mounting sets, which contact with oxygen, are cleaned and degreased R Enum 2048
production_date 4007 Product Date Product Date - Product date of the transmitter from the manufacturer R HartDate 2048
minimum_span_value 4029 Min span Valore intervallo minimo - Definisce la differenza più piccola consentita tra il valore di campo superiore e il valore di campo inferiore. R Float 8
burst_mode_select 0FFF Burst mode Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. R/W Enum 4096
byte_crc 4032 R Unsigned 4096
main_accuracy 4031 Accuracy Code Accuracy - error at normal operation conditions:t=23±20Catmospheric pressure = 84-106.7 kPà (from 630 to 800 mm Hg)working position in accordance with TU for a transmitter. R Enum 2048
diaph_material_code 4030 Isolator Matl Sensor Isolator Material- Construction material of a part of the module that comes in constact with the process material R Enum 2048
proc_material_code 402F Process Conn Matl Process Connector Material- Construction material of the process connector. R Enum 2048
burst_command_number 0FFD Burst command R Enum 0
Name ID Label Description Type Access Class