Loading…
Name ID Label Description Type Access Class
dummy_menu_entry 1B6D Nicht anwendbar R Enum 0
special_application 402E Special Application Oxygen modification means that working cavities of transmitters and parts of mounting sets, which contact with oxygen, are cleaned and degreased R Enum 2048
production_date 4007 Product Date Product Date - Product date of the transmitter from the manufacturer R HartDate 2048
minimum_span_value 4029 Min. Spanne Minimalwert f. Meßspanne- definiert die kleinste zulässige Differenz zwischen Meßanfang und Meßende. R Float 8
burst_mode_select 0FFF Burst-Modus Burst-Betriebsart- aktiviert die Burst-Betriebsart. Bei aktivierter Burst-Betriebsart sendet das Feldgerät dauernd HART Informationen aus, ohne Abfragen vom Host. R/W Enum 4096
byte_crc 4032 R Unsigned 4096
main_accuracy 4031 Accuracy Code Accuracy - error at normal operation conditions:t=23±20Catmospheric pressure = 84-106.7 kPà (from 630 to 800 mm Hg)working position in accordance with TU for a transmitter. R Enum 2048
diaph_material_code 4030 Isolator Matl Sensor Isolator Material- Construction material of a part of the module that comes in constact with the process material R Enum 2048
proc_material_code 402F Process Conn Matl Process Connector Material- Construction material of the process connector. R Enum 2048
burst_command_number 0FFD Burst command R Enum 0
Name ID Label Description Type Access Class