Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
MyCount1_classification | 4062 | Class | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
MyCount1_family | 4063 | Device family | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 0 |
MyCount1_serialNum | 4064 | Snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 0 |
MyCount1_write_dev_var_code | 4066 | Battery write dev var code | W | Enum | 2052 | |
fl_MyCount2 | 4068 | My Coun2 | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R/W | Float | 2050 |
MyCount2USL | 4069 | USL | R | Float | 0 | |
MyCount2LSL | 406A | LSL | R | Float | 0 | |
MyCount2Damping | 406B | Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R | Float | 0 |
MyCount2MinSpan | 406C | Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 0 |
MyCount2Units | 406D | Units | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 0 |