Loading…
Name ID Label Description Type Access Class
channel_5_minSpan 4064 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
channel_5_units 4065 Units Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 0
channel_5_data_quality 4068 PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 0
channel_5_limit_status 4069 LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 0
channel_5_family_status 406A Family status Device Family Status- Indicates additional status information on a device variable for a specific device family. R Enum 0
channel_5_classification 406B Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
channel_5_family 406C Device family Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 0
channel_5_serialNum 406D Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R/W Unsigned 0
channel_5_write_dev_var_code 406F Dev Var 0 write dev var code W Enum 0
channel_6_value 4071 Channel 6 Reading Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 2
Name ID Label Description Type Access Class