Loading…
Name ID Label Description Type Access Class
channel_3_value 403E Channel 3 Reading Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 2
channel_3_usl 403F USL R Float 0
channel_3_lsl 4040 LSL R Float 0
channel_3_damping 4041 Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R Float 0
channel_3_minSpan 4042 Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
channel_3_units 4043 Units Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 0
channel_3_data_quality 4046 PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 0
channel_3_limit_status 4047 LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 0
channel_3_family_status 4048 Family status Device Family Status- Indicates additional status information on a device variable for a specific device family. R Enum 0
channel_3_classification 4049 Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
Name ID Label Description Type Access Class