Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
flow_temperature_UTP | 4049 | Flow temp UTP | Upper Trim Point- Applied process input at which the last upper trim of the device variable was performed. | R | Float | 8 |
flow_temperature_TPS | 404A | FTemp trim support | Trim Points Supported- Indicates the trim points that are supported by the device variable during a trim procedure. | R | Enum | 8 |
flow_temperature_min_LTP | 404B | FTemp min LTP | Minimum Lower Trim Point- The lowest applied process value that can be used duirng a low trim procedure (ie, no value lower than this will be accepted by the instrument). | R | Float | 8 |
flow_temperature_max_LTP | 404C | FTemp max LTP | Maximum Lower Trim Point- The highest applied process value that can be used duirng a low trim procedure (ie, no value higher than this will be accepted by the instrument). | R | Float | 8 |
flow_temperature_min_UTP | 404D | FTemp min UTP | Minimum Upper Trim Point- The lowest applied process value that can be used duirng a high trim procedure (ie, no value lower than this will be accepted by the instrument). | R | Float | 8 |
flow_temperature_max_UTP | 404E | FTemp max UTP | Maximum Upper Trim Point- The highest applied process value that can be used duirng a high trim procedure (ie, no value higher than this will be accepted by the instrument). | R | Float | 8 |
flow_temperature_min_TD | 404F | FTemp min TD | Minimum Trim Differential- The minimum acceptable difference between the upper and lower trim points. | R | Float | 8 |
model_code | 4051 | Model code | R | ASCII | 2048 | |
transmitter_type | 4002 | Transmitter type | R | Enum | 2048 | |
range_code | 4052 | Range code | R | ASCII | 2048 | |
Name | ID | Label | Description | Type | Access | Class |