Loading…
Name ID Label Description Type Access Class
flowValue 4000 PV R Float 2
flowUnits 4001 PV Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure R/W Enum 0
flowFamily 4002 Flow Dev fmly Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 0
flowClassification 4003 Flow Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
flowPDQ 4004 PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 2
flowLS 4005 LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 2
flowStatus 4006 Family status Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 2
flowUSL 4007 USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 0
flowLSL 4008 LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 0
flowMinimumSpan 4009 Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
Name ID Label Description Type Access Class