Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
volume_flowDampingValue | 40B0 | Damp | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R | Float | 0 |
volume_flowUpdatePeriod_int | 41DD | Update Period | R | Unsigned | 0 | |
volume_flowSerialNumber | 40B2 | Snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 0 |
volume_flowSimulated | 40B3 | Simulate | W | Enum | 0 | |
volume_resetValue | 40BA | Volume with reset | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 2 |
volume_resetUnits | 40BB | Vol unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 0 |
volume_resetFamily | 40BC | Device family | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 0 |
volume_resetClassification | 40BD | Volume | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
volume_resetPDQ | 40BE | PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 2048 |
volume_resetLS | 40BF | LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 2048 |
Name | ID | Label | Description | Type | Access | Class |