Name ID Label Description Type Access Class
mass_upper_transducer_limit 4011 Upper Xducer Limit Upper Xducer Limit - Probe calibration factor, mass flow rates exceeding this value are outside the original calibration range. R/W Float 8
temp_lower_transducer_limit 4024 Lower Xducer Limit Lower Xducer Limit - Probe calibration factor, temperatures less than this value are outside the original calibration range. R/W Float 8
temp_upper_transducer_limit 4023 Upper Xducer Limit Upper Xducer Limit - Probe calibration factor, temperatures exceeding this value are outside the original calibration range. R/W Float 8
current 4008 PV Loop Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes. R/W Float 66
SV_current 4018 SV Loop Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 66
fault 4009 Fault State Fault State - Select how the Analog output of the TA2 will respond if a fault in the instrument is detected. R/W Enum 65
flow1_set4mA 400B PV Lwr Range Val PV Lwr Range Val - Enter the 4 mA point using the units of measurement previously selected. R/W Float 64
flow1_set20mA 400C PV Upr Range Val PV Upr Range Val - Enter the 20 mA point using the units of measurement previously selected. R/W Float 64
mass1_set4mA 4014 PV Lwr Range Val PV Lwr Range Val - Enter the 4 mA point using the units of measurement previously selected. R/W Float 64
mass1_set20mA 4015 PV Upr Range Val PV Upr Range Val - Enter the 20 mA point using the units of measurement previously selected. R/W Float 64
Name ID Label Description Type Access Class