Loading…
名称 ID 标签 描述 类型 访问 分类
statusinfo_15 406F IPC Ack IPC Ack - Internal communications error; consult Factory. 枚举 2050
TargetsMode 4070 Mode Review all Targets detected by the transmitter including false targets (targets other than Level). Ensure that the proper Level target is shown then run Target Rejection routine. If reported Level is close to actual and the quality number is > 20, it is probably correct. Targets can be viewed in Level or Distance mode. 读/写 枚举 2048
TargRejStatus 400F Status The Target Rejection routine detects, stores, and cancels false targets to ensure detection of the proper level signal. The No False Target Rejection warning message will be displayed if this algorithm is not enabled. Do not proceed with False Target Rejection procedure until confirming Level and Quality values in Targets menu. False Target Rejection should be run with vessel at or near empty when all targets are exposed; re-run this routine if initial calibration is done with significant liquid in vessel. The false target profile will be disabled and this routine should be re-run if antenna or tank parameters are modified or when launcher is repositioned. 枚举 2050
TargRejStatusType 40AC Target Rej Type 枚举 2048
TargRejLevel 4145 Targ Rej Level Factory parameter, displayed for diagnostic purposes only. 浮点 2048
TargRejAction_requested 40AD 枚举 4096
PeakListType_requested 40AE 枚举 4096
PeakList_number_of_PTP_peaks 40AF 无符号 4096
PTP_Peak1Quality 40B0 无符号 4096
PTP_Peak2Quality 40B1 无符号 4096
名称 ID 标签 描述 类型 访问 分类